Medical Products by Ardus
CADD Pumps I CADD Prizm VIP PCA Pump
CADD Prizm VIP models 6100 & 6101
Cadd Prizm VIP 6100/6101
Save up to 80% on pre-owned Cadd Prizm VIP 6100/6101 ambulatory pumps.
Request A QUOTE!
Product Specifications
- Pump Resolution:
- Standard reservoir or set = 0.050ml/pump stroke nominal. High volume set = 0.100 ml/pump stroke nominal
- Dimensions:
- 1.7" D x 4.1" W x 5.6" H, excluding cassette
- Weight:
- 20 oz including 9 volt battery and empty 100 ml reservoir
- Power Source:
- 9 volt alkaline or lithium battery, External Power Source, or AC Adapter
- System Delivery Accuracy:
- ±6% nominal
PCA Delivery Mode Specifications
- Reservoir Volume:
- 1-9999 or Not in Use; programmable in 1 ml increments, displayed in 0.1 ml increments
- Concentration:
- mg/ml, mcg/ml
- Continuous Rate:
- 0-30 ml/hr or the mg or mcg equivalent
- Demand Dose:
- 0-9.9 ml, Delivery rate is 125 ml/hr nominal
- Demand Dose Lockout:
- 5 min-24 hours in the following increments:
- - 1 min for values between 5 and 20 minutes
- - 5 min-24 hours in the following increments:
- Max Doses Per Hour:
- 1-12 doses in 1 dose increments
- Demand Doses Given:
- 0-999
- Demand Dose Attempts:
- 0-999
- Given:
- 0-99999.99 in 0.01 unit increments
- Clinician Bolus:
- 0.1 ml - 20.0 ml or mg or mcg equivalent, delivery rate is 125 ml/hr nominal
Continuous Delivery Mode Specifications
- Reservoir Volume:
- 1-9999 or Not in Use; programmable in 1 ml increments, displayed in 0.1 ml increments
- Continuous Rate:
- 0.1-350 ml/hr in the following increments:
- - 0.1 for values between 0.1-100
- - 1 for values between 100-350
- Given:
- 0-99999.9 in 0.1 unit increments
TPN Delivery Mode Specifications
- Reservoir Volume:
- 10.0 - 9990 or Not in Use; programmable in 1 ml increments, displayed in 0.1 increments
- Infusion Volume:
- 10-9990 ml in 10 ml increments
- Infusion Period:
- 0 hrs 10 min - 99 hrs 40 min in 10 minute increments
- Taper Down Period:
- 0 hrs 0 min - 99 hrs 50 min in 10 minute increments
- Plateau Rate:
- Calculated by pump; 10-350 ml/hr
- KVO Rate:
- Calculated by pump; 1/10 of Plateau Rate up to 5 ml/hr
- Given:
- 0-99999 in 0.1 unit increments
Intermittent Delivery Mode Specifications
- Reservoir Volume:
- 1-9999 or Not in Use; programmable in 1 ml increments, displayed in 0.1 ml increments
- Dose Volume:
- 0.1-1000 ml in the following increments:
- - 0.1 for values between 0.0 and 100
- - 1 for values between 100 and 1000
- Dose Duration:
- 1 min-24 hrs in the following increments:
- - 1 min for values between 1 min and 10 min
- - 5 min for values above 10 min
- - Duration is limited by Dose Volume so that rate does not exceed 350 ml/hr
- Dose Cycle:
- 10 min - 96 hrs in 5 minute increments
- KVO Rate:
- 0-10 ml/hr in 0.1 ml increments
- Next Dose Start Time:
- 10 min - 96 hrs X min (where X equals a 10 minute increment in the 96th hour)
- Given:
- 0-99999.9 in 0.1 unit increments
- Time Remaining:
- Dose and Cycle display in 1 min increments
For service, parts, PM or rental see our Services section |